新房裝修電路敷設需要注意以下事項
-
來源:金環宇電線電纜發布(bu)日期:2020-04-13 11:36
家庭裝修電路需改造,那么改造是家居裝修中的隱蔽工程,表面看似安全的背后可能就潛藏著諸多隱患。電路改造不好,很容易就給家居安全帶來威脅,甚至危及生命安全,那么,在裝修時,電路改造要注意哪些事項呢?下面金環宇電線電纜小編(bian)就詳細(xi)為(wei)您介紹裝(zhuang)修(xiu)電(dian)(dian)(dian)(dian)(dian)路(lu)改(gai)造的(de)施工要點。電(dian)(dian)(dian)(dian)(dian)路(lu)問(wen)題(ti)關(guan)系到家里人的(de)生命安全(quan)。室內電(dian)(dian)(dian)(dian)(dian)路(lu)布(bu)線(xian),要采用多(duo)路(lu)化的(de)設計方(fang)式,做(zuo)到空調(diao)、廚房、衛生間、客(ke)廳、臥室、電(dian)(dian)(dian)(dian)(dian)腦及大功(gong)率電(dian)(dian)(dian)(dian)(dian)器分路(lu)布(bu)線(xian);插座、開關(guan)要分開設置,各分支電(dian)(dian)(dian)(dian)(dian)路(lu)上,應安裝(zhuang)帶漏電(dian)(dian)(dian)(dian)(dian)保(bao)護功(gong)能(neng)的(de)微型斷路(lu)器開關(guan)。另外(wai),強(qiang)電(dian)(dian)(dian)(dian)(dian)線(xian)路(lu),要與弱電(dian)(dian)(dian)(dian)(dian)線(xian)路(lu)分開一定距離,電(dian)(dian)(dian)(dian)(dian)話通訊線(xian)纜、音(yin)響多(duo)媒體(ti)線(xian)纜、寬帶網絡(luo)線(xian)纜等弱電(dian)(dian)(dian)(dian)(dian)線(xian)路(lu),應該設計合理(li),符(fu)合規范要求(qiu)。
1、墻身、地面開(kai)線(xian)(xian)槽之前,先(xian)用(yong)墨(mo)盒彈(dan)線(xian)(xian),以(yi)便確定位置(zhi)。管子外側(ce)與(yu)墻面之間(jian),應留15mm左(zuo)右的(de)抹灰(hui)層(ceng),以(yi)防止抹灰(hui)施工(gong)以(yi)后的(de)墻面開(kai)裂。
2、未經允(yun)許,不(bu)許隨意(yi)破(po)壞、更改公共電氣設施(shi),如避雷地線、保護接地、等電位聯結,等設置。
3、電源線管(guan)暗埋(mai)時,應考(kao)慮與弱(ruo)電管(guan)線等保持500mm以上距離,電線管(guan)與熱水管(guan)、煤氣管(guan)之間(jian)的平行距離不小于300mm。
4、墻面線管走向,盡可能減少(shao)轉彎,并且要(yao)避開(kai)壁鏡,家具等物的安裝(zhuang)位置(zhi),防止被電錘、釘(ding)子(zi)損傷。
5、如(ru)無(wu)特殊要求,在(zai)同一套房屋內(nei)部(bu),墻(qiang)壁上(shang)的開關(guan),離地(di)(di)1200-1500mm之(zhi)間,距門邊150-200mm處,墻(qiang)壁上(shang)的插(cha)(cha)座(zuo),離地(di)(di)300mm左右,墻(qiang)壁上(shang)的插(cha)(cha)座(zuo)開關(guan),分別在(zai)同一水平線上(shang),高(gao)(gao)度誤差(cha),小(xiao)(xiao)于8mm,并(bing)列安裝時(shi),高(gao)(gao)度誤差(cha),小(xiao)(xiao)于1mm,并(bing)且不(bu)被推拉(la)門、家具等物遮擋(dang)。
6、各種強(qiang)電(dian)、弱電(dian)插座接口,寧多(duo)勿(wu)缺(que),室內床(chuang)頭(tou)兩側,應設(she)置電(dian)源(yuan)插座及一個電(dian)話插座,電(dian)腦桌附近,客廳電(dian)視柜背(bei)景(jing)墻上,都應設(she)置三個以上的(de)電(dian)源(yuan)插座,并設(she)置相應的(de)電(dian)視、電(dian)話、多(duo)媒體、寬帶(dai)網絡等插座。
7、電(dian)視、電(dian)話、多媒(mei)體音響、寬(kuan)帶網絡(luo)等弱(ruo)電(dian)線路的(de)鋪設方(fang)(fang)法(fa)及要求,與(yu)電(dian)源線的(de)鋪設方(fang)(fang)法(fa)相同(tong),其插座(zuo)或線盒,與(yu)電(dian)源插座(zuo)并列安裝,但是(shi),強電(dian)線路與(yu)弱(ruo)電(dian)線路,不(bu)允許共用一套管子。
8、所(suo)有入墻電線,采用直(zhi)徑16mm以上的PVC阻燃管埋設(she),導線占管徑<40%空間,與盒底連接(jie),使用專用接(jie)口(kou)件。
9、使用(yong)導線管(guan)時(shi),電源線管(guan)從地(di)面(mian)穿出應(ying)做合理的轉彎半徑,特別(bie)注意(yi),在(zai)地(di)面(mian)下,必須(xu)使用(yong)套管(guan),并加膠連(lian)接緊密,地(di)面(mian)沒有封(feng)閉(bi)之(zhi)前,必須(xu)保護好PVC管(guan)套,不允許有破裂損傷(shang);鋪地(di)板磚時(shi),PVC套管(guan),應(ying)被水(shui)泥沙漿完全覆蓋。
10、配線(xian)(xian)時,相(xiang)線(xian)(xian)與零線(xian)(xian)的顏(yan)色(se)應(ying)不同(tong);同(tong)一住宅(zhai)相(xiang)線(xian)(xian)火線(xian)(xian)(L)顏(yan)色(se)應(ying)統一,比如,相(xiang)線(xian)(xian)火線(xian)(xian),使(shi)用黃(huang)色(se),或者使(shi)用綠色(se),或者使(shi)用紅色(se),零線(xian)(xian)(N)用淡藍(lan)色(se),保護(hu)接(jie)地(di)線(xian)(xian)(PE)用黃(huang)綠雙色(se)線(xian)(xian)。
11、線(xian)管(guan)穿(chuan)(chuan)(chuan)線(xian)之(zhi)前,應(ying)將(jiang)直(zhi)接頭打上PVC膠(jiao)水,以免進水。電源線(xian)穿(chuan)(chuan)(chuan)管(guan)時(shi),應(ying)將(jiang)導線(xian)取直(zhi)再穿(chuan)(chuan)(chuan)管(guan),不可(ke)中途(tu)拔、拉管(guan)接頭;弱電線(xian)路中,穿(chuan)(chuan)(chuan)線(xian)時(shi)用力時(shi)不可(ke)過猛,以免導線(xian)斷(duan)心。
12、電源分支接頭(tou),應接在插(cha)座盒、開關盒、燈頭(tou)盒內,每(mei)個接頭(tou)接線,不宜超過兩根,線在盒內,應有適當(dang)的(de)余量。
13、音響線出入墻(qiang)面,應做底(di)盒。多芯電話(hua)線的接(jie)頭(tou)處,護套管口,用膠(jiao)帶包(bao)扎緊,以免電話(hua)線受潮,發生串音等故障(zhang)。
14、電視天線接線,必須采用分支器(qi),并留有檢查口。
15、管(guan)中電源(yuan)線,不可(ke)(ke)(ke)有(you)接(jie)頭、不可(ke)(ke)(ke)將電源(yuan)線,裸露在吊頂上或直接(jie)抹入墻中,以(yi)保證電源(yuan)線可(ke)(ke)(ke)以(yi)拉動或更換(huan)。
16、導(dao)線連接(jie)(jie)堅(jian)固,接(jie)(jie)頭不受拉(la)力,包扎(zha)嚴密(mi),采(cai)用(yong)螺(luo)釘(螺(luo)帽)連接(jie)(jie)時(shi),電(dian)線無絕緣(yuan)(yuan)距離不大于3mm,銅芯線間連接(jie)(jie),應用(yong)壓接(jie)(jie)或絞接(jie)(jie)法(fa),絞接(jie)(jie)長(chang)度,不小于5圈,裸(luo)露電(dian)線,必(bi)須先用(yong)防水膠帶包扎(zha)后,再纏繞黑膠布(bu),無絕緣(yuan)(yuan)層破損等缺陷(xian),經檢驗(yan)認可(ke)。
17、穿管的電線、信(xin)號線、電話(hua)線等都進行檢測,以確認是(shi)否線間短(duan)路、對地短(duan)路、斷線等,確認無(wu)誤后(hou)再進行埋線管。
18、單相(xiang)(xiang)兩(liang)孔插座(zuo)(zuo)的接(jie)線(xian)(xian),面(mian)對(dui)插座(zuo)(zuo):左(zuo)零(ling)右(you)相(xiang)(xiang)(即,左(zuo)邊為零(ling)線(xian)(xian),右(you)邊為火線(xian)(xian)),單相(xiang)(xiang)三孔,正(zheng)上方為地(di)(di)線(xian)(xian)。所(suo)有單相(xiang)(xiang)插座(zuo)(zuo),均符合(he)“左(zuo)零(ling)右(you)相(xiang)(xiang),接(jie)地(di)(di)在(zai)上”的原(yuan)則。
19、插座、開(kai)關安裝,要牢(lao)固,四周(zhou)無縫隙,廚房、衛生間(jian)內及室內及室外安裝的(de)開(kai)關,應(ying)采用帶防(fang)濺盒的(de)開(kai)關。
20、空(kong)調供電,用(yong)(yong)16A三孔插座,高度在(zai)1500mm以(yi)下的所有(you)(you)插座,應(ying)安裝具有(you)(you)保護(hu)擋板的插座,以(yi)免兒童觸(chu)摸,衛(wei)生間(jian)(jian)內(nei)部,宜作局部等(deng)電位聯結端子,插座采(cai)用(yong)(yong)防(fang)水(shui)防(fang)濺型,并遠離水(shui)源(yuan)。照明開關(guan),應(ying)設在(zai)門外,鏡前燈、浴霸,衛(wei)生間(jian)(jian)內(nei)部,宜選用(yong)(yong)防(fang)水(shui)開關(guan)。
21、為了生活舒適方便,臥室應(ying)采用雙控開(kai)(kai)關,廚(chu)房電(dian)源(yuan)插(cha)座,應(ying)并(bing)列設置開(kai)(kai)關,控制電(dian)源(yuan)通斷。
22、插座、開關面(mian)板(ban)固定時(shi),應用(yong)配套的螺釘(ding),不得使用(yong)木(mu)螺釘(ding)或石(shi)膏(gao)板(ban)螺絲代替,以(yi)免損壞底盒,開關安裝方向(xiang)一致。
23、配(pei)(pei)電箱(xiang),應根(gen)據(ju)室內用電設(she)備(bei)的(de)(de)不(bu)同功(gong)率,分(fen)別配(pei)(pei)線(xian)(xian)供電;大功(gong)率家電設(she)備(bei),應獨立配(pei)(pei)線(xian)(xian)安裝(zhuang)插(cha)座。配(pei)(pei)電箱(xiang)內的(de)(de)電線(xian)(xian)排(pai)列,要(yao)(yao)整齊,插(cha)座照明各(ge)路開關,要(yao)(yao)分(fen)清,壓(ya)接配(pei)(pei)件齊全,壓(ya)接導(dao)線(xian)(xian)的(de)(de)回轉(zhuan)方(fang)向(xiang),要(yao)(yao)正確,斷路器接線(xian)(xian)牢固,在斷路器接線(xian)(xian)端子上,不(bu)得將不(bu)同線(xian)(xian)徑的(de)(de)導(dao)線(xian)(xian)在同一端壓(ya)接,配(pei)(pei)電箱(xiang)分(fen)路,要(yao)(yao)平衡,要(yao)(yao)標明各(ge)個回路。
- 上一篇:金環宇電線電纜教您辨別高品質電線電纜