兩臺4KW的水泵要用鋁線需要多少平方?
-
來源:互聯網發布日期:2019-07-24 09:42
現有兩臺4KW水(shui)泵,一起工作,距離(li)有300多米(mi),電線要用(yong)鋁線需要多少平方的線?
2臺4KW=8KW電(dian)(dian)機(ji)而定(ding)電(dian)(dian)流(liu)(liu)為(wei)(wei)16安培,線(xian)(xian)路(lu)(lu)(lu)距(ju)離過(guo)長(chang),電(dian)(dian)壓(ya)在傳輸過(guo)程(cheng)損耗很大(da),造成的電(dian)(dian)壓(ya)降也較大(da),按(an)變壓(ya)器端(duan)(duan)電(dian)(dian)壓(ya)400V時,線(xian)(xian)路(lu)(lu)(lu)末(mo)端(duan)(duan)允許電(dian)(dian)壓(ya)降(單(dan)線(xian)(xian)):U=15V,末(mo)端(duan)(duan)線(xian)(xian)電(dian)(dian)壓(ya)約為(wei)(wei)370V,電(dian)(dian)機(ji)總功率(lv)為(wei)(wei)4KW,額定(ding)電(dian)(dian)流(liu)(liu):I≈16A,線(xian)(xian)路(lu)(lu)(lu)長(chang)度:L=300米根據負(fu)載電(dian)(dian)流(liu)(liu)求(qiu)鋁(lv)線(xian)(xian)(單(dan)線(xian)(xian))電(dian)(dian)阻:R=U/I=15/16=0.94(Ω)2》求(qiu)鋁(lv)芯電(dian)(dian)線(xian)(xian)(單(dan)線(xian)(xian))截面:S=ρ×L/R=0.0283×300/1.9≈8.49/0.94≈9.03(平方(fang))所以(yi)應選擇10平方(fang)。
鋁芯線(xian)(xian)相對比銅芯線(xian)(xian)的(de)價格要低(di),可以(yi)考慮16平方的(de)電線(xian)(xian)。