一、電力電纜通道敷設概況
隨(sui)著(zhu)城市建設的發展,人們對居(ju)住環境有了(le)更高的要求。在城市建設和改造規(gui)劃中(zhong),對新建片區、繁華地帶往往要求所有管(guan)線(xian)在地下(xia)敷(fu)設,作為“城市生命(ming)線(xian)”之一(yi)的電纜更是如此。
目前,電(dian)纜(lan)的(de)敷設方(fang)式(shi)有直埋、電(dian)纜(lan)溝(gou)、排管(guan)(guan)、頂(ding)管(guan)(guan)、電(dian)纜(lan)隧道等,它們有著不同的(de)技(ji)術結構特點(dian),因而適用的(de)環境也有較(jiao)大區別。
1.直(zhi)埋敷設(she):直(zhi)埋敷設(she)是指將電(dian)纜直(zhi)接埋設(she)于(yu)地面下(xia)的(de)敷設(she)方式,其(qi)適用于(yu)電(dian)纜線路(lu)不(bu)太密(mi)集(ji)的(de)城市(shi)(shi)地下(xia)走廊,如市(shi)(shi)區(qu)人行道、公共(gong)綠地、建(jian)筑物邊緣地帶等。電(dian)纜埋設(she)深(shen)度為0.7~1.5m,覆蓋15cm細土或細沙,并(bing)用水泥蓋板(ban)保(bao)護。
2.電纜溝敷(fu)設:電纜溝敷(fu)設是指將電纜敷(fu)設于(yu)預先建好的電纜溝中的安裝(zhuang)方(fang)式,其適用于(yu)地(di)面載(zai)重負荷較(jiao)輕的電纜線路(lu)路(lu)徑,如(ru)工廠廠區、發電廠和變電站內。在(zai)結構特點上(shang),電纜溝采用混凝(ning)土或磚砌結構,頂部用蓋(gai)板覆蓋(gai),溝內設單(dan)側或雙側支(zhi)架。
3.排(pai)管(guan)敷(fu)(fu)設(she):電力(li)排(pai)管(guan)敷(fu)(fu)設(she)是指將電纜敷(fu)(fu)設(she)于預先(xian)建好的(de)(de)地(di)下排(pai)管(guan)中(zhong)的(de)(de)安裝方式,其適用于城市交通比較(jiao)繁忙,有(you)機動(dong)車等(deng)重(zhong)載,敷(fu)(fu)設(she)電纜條數比較(jiao)多的(de)(de)地(di)段。在結構特(te)點上,排(pai)管(guan)敷(fu)(fu)設(she)必須(xu)有(you)電力(li)排(pai)管(guan)和工(gong)井兩種(zhong)土建設(she)施。采用這種(zhong)方式敷(fu)(fu)設(she),基(ji)本(ben)上消除(chu)了(le)電纜外力(li)機械損(sun)傷的(de)(de)可能性。
4.頂管敷(fu)設(she):頂管敷(fu)設(she)一(yi)般(ban)采用(yong)水泥(ni)管作頂管,管內再敷(fu)設(she)塑料管或作支架(jia),其適用(yong)于不宜開挖(wa)、且(qie)路徑短的路段(如鐵路干線(xian)),一(yi)般(ban)配合(he)其它敷(fu)設(she)方(fang)式使用(yong)。
5.電纜(lan)(lan)隧道(dao)(dao)(dao)敷(fu)設(she):電纜(lan)(lan)隧道(dao)(dao)(dao)敷(fu)設(she)是指將(jiang)電纜(lan)(lan)敷(fu)設(she)于地下隧道(dao)(dao)(dao)中的(de)電纜(lan)(lan)安裝方式,其適用(yong)于電廠或變(bian)電站(zhan)的(de)進出(chu)線通(tong)(tong)道(dao)(dao)(dao),電纜(lan)(lan)并列在(zai)20根以上(shang)的(de)城市(shi)重(zhong)要道(dao)(dao)(dao)路(lu)以及有(you)多回(hui)路(lu)高壓電纜(lan)(lan)從同一(yi)地段跨(kua)越內河等(deng)場所。在(zai)結(jie)構特點上(shang),隧道(dao)(dao)(dao)中有(you)高1.9~2.0m的(de)人行通(tong)(tong)道(dao)(dao)(dao),有(you)照明(ming)、通(tong)(tong)風和自動排(pai)水等(deng)裝置。
對于(yu)電(dian)纜敷設(she)方式(shi)的(de)(de)選擇需(xu)結合(he)具體的(de)(de)電(dian)纜線路(lu)路(lu)徑(jing)環(huan)境,應(ying)根(gen)據(ju)統一規劃、安全運行(xing)和(he)經(jing)濟合(he)理等原則確定敷設(she)方式(shi)和(he)相(xiang)應(ying)的(de)(de)附(fu)屬土建設(she)施規模。
此外,電纜(lan)通道的敷設需(xu)要同(tong)城市(shi)整(zheng)體規劃相(xiang)結合,尤(you)其是城市(shi)環境(jing)、道路(lu)發展、地下空間規劃等(deng)等(deng),盡量減少對城市(shi)道路(lu)及(ji)其它地下管線的影響和干擾(rao)。
二、電纜通道規劃思路與(yu)原(yuan)則
從不(bu)同規劃區(qu)(qu)(qu)(qu)域的(de)(de)(de)通(tong)(tong)道(dao)發展模式來看,城市(shi)市(shi)區(qu)(qu)(qu)(qu)范圍內(nei)屬于負荷(he)密(mi)(mi)(mi)度高(gao)、變電站(zhan)密(mi)(mi)(mi)集(ji)(ji)的(de)(de)(de)地區(qu)(qu)(qu)(qu),應集(ji)(ji)中建(jian)(jian)立(li)網(wang)狀(zhuang)的(de)(de)(de)通(tong)(tong)道(dao)結構,提高(gao)通(tong)(tong)道(dao)的(de)(de)(de)貫(guan)通(tong)(tong)性,使電纜能(neng)進行靈(ling)活多變的(de)(de)(de)敷(fu)設(she),給(gei)電網(wang)網(wang)架(jia)的(de)(de)(de)建(jian)(jian)設(she)提供較大的(de)(de)(de)余地。城市(shi)市(shi)區(qu)(qu)(qu)(qu)外圍屬于負荷(he)密(mi)(mi)(mi)度不(bu)高(gao)、變電站(zhan)分布較疏的(de)(de)(de)地區(qu)(qu)(qu)(qu),電力通(tong)(tong)道(dao)主(zhu)要還是集(ji)(ji)中在基建(jian)(jian)站(zhan)周圍,相互聯(lian)接較少(shao),所以電力通(tong)(tong)道(dao)的(de)(de)(de)發展應以市(shi)政主(zhu)干道(dao)路(lu)為(wei)主(zhu),次通(tong)(tong)道(dao)為(wei)輔(fu)。
從不同(tong)電壓等級的通道發展模式來看,220kV和500kV變電站出口(kou)可以建設電力隧道,便于(yu)敷設大截面電纜,增加線(xian)路輸送容量(liang);35kV以上電壓等級變電站的出口(kou)通道需要保證多(duo)個(ge)方向(xiang),便于(yu)10kV電纜能在出站后迅速散開(kai),以免(mian)造成出口(kou)通道擁(yong)堵;10kV電纜盡可能采用(yong)排管敷設,確(que)實有困難至少(shao)應采用(yong)穿(chuan)管敷設。至遠(yuan)景年,10kV電纜全(quan)部采用(yong)排管敷設。
對(dui)于(yu)城市(shi)配電(dian)網絡的(de)通道(dao)(dao)(dao)建(jian)設(she),應結合市(shi)政(zheng)道(dao)(dao)(dao)路(lu)主干道(dao)(dao)(dao)同(tong)步建(jian)設(she)電(dian)力通道(dao)(dao)(dao)主干道(dao)(dao)(dao),形(xing)(xing)成(cheng)較為清晰(xi)明確的(de)主干網絡,結合110-35kV變(bian)電(dian)站同(tong)步建(jian)設(she)電(dian)力通道(dao)(dao)(dao)次干道(dao)(dao)(dao),形(xing)(xing)成(cheng)以變(bian)電(dian)站為中(zhong)心的(de)次干網絡,確保10kV電(dian)纜線路(lu)規劃通道(dao)(dao)(dao)的(de)落實。
綜上所述(shu),通(tong)道(dao)規劃應(ying)結(jie)合(he)城市不(bu)同區域的發展模式而遵循一(yi)定的原則,通(tong)道(dao)在建設上要留有余地,充分考(kao)慮今后(hou)新建電(dian)力通(tong)道(dao)或增加通(tong)道(dao)規模的可能性。
三(san)、電纜通道制作流程(cheng)和(he)電纜敷設管理(li)
(一)電纜通(tong)道(dao)制作管理
結(jie)合市(shi)政道(dao)路改(gai)造負(fu)責新(xin)建電(dian)纜(lan)通道(dao)工程,項目經理(li)全過(guo)程管理(li)保質(zhi)保量按期圓(yuan)滿完(wan)成通道(dao)建設。
1.現場(chang)施(shi)(shi)工技術(shu)一次交底(各(ge)管線單(dan)位、配(pei)電項目(mu)(mu)經理(li)、監(jian)理(li)設計(ji)、測(ce)繪(hui)院、地(di)下管線所、施(shi)(shi)工方項目(mu)(mu)經理(li)、技術(shu)負(fu)責人)
交(jiao)(jiao)底主(zhu)要(yao)內容:依(yi)據設計圖查(cha)看(kan)現場實(shi)際情況進行對比,溝通施(shi)工難(nan)度,制定施(shi)工具體(ti)方案(例如地(di)下管線(xian)交(jiao)(jiao)叉作業、規(gui)避施(shi)工風(feng)險。交(jiao)(jiao)管封閉道路施(shi)工、市政開挖),配合(he)測(ce)(ce)(ce)繪(hui)(hui)院測(ce)(ce)(ce)繪(hui)(hui)做準(zhun)備,做出(chu)最終準(zhun)確(que)的(de)測(ce)(ce)(ce)繪(hui)(hui)報告,保證(zheng)施(shi)工安全(quan)無誤的(de)實(shi)施(shi)。
2.要求(qiu)施工單(dan)位(wei)施工前做好準(zhun)備(bei)工作。
具體內容(rong):開挖證、道路封閉施工(gong)(gong)(gong)、施工(gong)(gong)(gong)臨時(shi)用水用電(dian)、夜間施工(gong)(gong)(gong)手續辦理,文明施工(gong)(gong)(gong)告(gao)示,放線(xian)(放樣)。
3.組織現場(chang)施(shi)工(gong)(gong)技術二(er)次交(jiao)底(各管(guan)(guan)線(xian)單位、配電(dian)項目經(jing)(jing)理、監理、設計、測(ce)繪院、地下管(guan)(guan)線(xian)所、施(shi)工(gong)(gong)方項目經(jing)(jing)理、技術負責人)
交底主要內容:明(ming)確測繪院(yuan)定位以及勘測結果(guo)與現場實(shi)際(ji)情況相符,解(jie)決預(yu)測施工中存在的困難(nan)和確定進場日(ri)期。
4.施(shi)工進場(待(dai)所有涉及到施(shi)工的(de)行政手續辦(ban)理(li)(li)齊全)與監理(li)(li)監督施(shi)工隊(dui)施(shi)工質量、進度(du)與安(an)全(文明施(shi)工)
具體內容(rong)(rong):(1)人(ren)員到位,開(kai)(kai)工(gong)(gong)(gong)(gong)會,分配工(gong)(gong)(gong)(gong)作(zuo)任(ren)務(落實到個人(ren))。工(gong)(gong)(gong)(gong)作(zuo)票提前(qian)兩天開(kai)(kai)好。(2)使用專業施(shi)(shi)工(gong)(gong)(gong)(gong)拍攝(she)軟件(jian)記錄每日(ri)施(shi)(shi)工(gong)(gong)(gong)(gong)內容(rong)(rong)、施(shi)(shi)工(gong)(gong)(gong)(gong)進(jin)度、簽(qian)證資料搜(sou)集與工(gong)(gong)(gong)(gong)程量的統計(ji)工(gong)(gong)(gong)(gong)作(zuo)。(3)張(zhang)貼施(shi)(shi)工(gong)(gong)(gong)(gong)文明告示、項目銘牌。(4)搭設(she)施(shi)(shi)工(gong)(gong)(gong)(gong)圍擋(dang)(5)挖機(ji)進(jin)場(chang)破碎開(kai)(kai)挖溝(gou)槽,設(she)專人(ren)監護。
5.作業工序及內容
電力通道排管施(shi)工(gong)工(gong)藝流(liu)程(cheng)(與監理、設計監督對施(shi)工(gong)質量的(de)把關(guan)、評價)
(1)溝槽開挖(wa)。(2)余土(tu)外運。(3)主材進(jin)場(各規(gui)格(ge)鋼(gang)筋、混(hun)凝(ning)(ning)(ning)土(tu)),現場通(tong)知(zhi)監(jian)理單(dan)位監(jian)督取樣確認簽(qian)字(鋼(gang)筋須所有規(gui)格(ge)均需(xu)截斷作為大樣,各個規(gui)格(ge)一段(duan)即可。混(hun)凝(ning)(ning)(ning)土(tu)現場在澆(jiao)筑(zhu)模內(nei)澆(jiao)筑(zhu)試塊,待干),送至第三方(fang)具備(bei)相關資質的檢測(ce)(ce)單(dan)位進(jin)行(xing)送樣檢測(ce)(ce)并(bing)出具檢測(ce)(ce)報告(gao)(gao)。檢測(ce)(ce)報告(gao)(gao)合格(ge)后(hou)(hou)方(fang)可使用材料(liao)進(jin)行(xing)施(shi)工。(4)墊層(ceng)澆(jiao)筑(zhu)。(5)待墊層(ceng)凝(ning)(ning)(ning)固(gu)后(hou)(hou)放管枕,并(bing)排管子,用鐵絲綁扎方(fang)法固(gu)定管子。(6)混(hun)凝(ning)(ning)(ning)土(tu)澆(jiao)筑(zhu),采用2層(ceng)管子澆(jiao)筑(zhu)一遍,第二遍澆(jiao)筑(zhu)前(qian)排管頂部扎鋼(gang)筋網覆(fu)蓋(gai)后(hou)(hou)澆(jiao)筑(zhu),并(bing)同時用震(zhen)動棒震(zhen)動。(7)鋼(gang)筋加(jia)固(gu)二次澆(jiao)筑(zhu)。(8)混(hun)凝(ning)(ning)(ning)土(tu)灑水(shui)保(bao)養。(9)待混(hun)凝(ning)(ning)(ning)土(tu)澆(jiao)筑(zhu)7天(tian)后(hou)(hou)挖(wa)機回土(tu)之(zhi)標高(gao)。
6.電纜井(jing)施工工藝流(liu)程(cheng)與(yu)監(jian)理(li)監(jian)督質量、安全、工藝標準及流(liu)程(cheng)的每個環節進行(xing)把關
(1)開(kai)挖電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)基(ji)坑,2分之(zhi)1深(shen)度后(hou)用挖機把鋼(gang)板(ban)樁敲打(da)至電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)底部(bu)(bu)下方1.5米(mi)深(shen)度。(2)電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)基(ji)坑挖好(hao)后(hou),人工開(kai)挖一(yi)只集水井(jing)(jing)(jing)(jing)(jing),在電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)中間位置。(3)墊層(ceng)(ceng)(ceng)澆(jiao)筑(zhu)(zhu),C30混(hun)(hun)凝(ning)(ning)土澆(jiao)筑(zhu)(zhu)第一(yi)層(ceng)(ceng)(ceng)墊層(ceng)(ceng)(ceng)。(4)扎(zha)鋼(gang)筋(jin),待(dai)電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)底部(bu)(bu)墊層(ceng)(ceng)(ceng)凝(ning)(ning)固(gu)后(hou)扎(zha)鋼(gang)筋(jin),鋼(gang)筋(jin)雙層(ceng)(ceng)(ceng)過底(5)鋼(gang)筋(jin)扎(zha)好(hao)后(hou)澆(jiao)筑(zhu)(zhu)電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)底部(bu)(bu)混(hun)(hun)凝(ning)(ning)土,澆(jiao)筑(zhu)(zhu)積(ji)水井(jing)(jing)(jing)(jing)(jing)。(6)制模(mo)板(ban)待(dai)底部(bu)(bu)混(hun)(hun)凝(ning)(ning)土凝(ning)(ning)固(gu)后(hou)開(kai)始(shi)制模(mo)板(ban),制雙邊內外模(mo)板(ban)。(7)扎(zha)電(dian)(dian)纜(lan)(lan)(lan)井(jing)(jing)(jing)(jing)(jing)頂部(bu)(bu)鋼(gang)筋(jin),預(yu)留2只井(jing)(jing)(jing)(jing)(jing)口。(8)混(hun)(hun)凝(ning)(ning)土檢測,通知監理(li)驗收鋼(gang)筋(jin)。(9)混(hun)(hun)凝(ning)(ning)土澆(jiao)筑(zhu)(zhu),振動棒震動。(10)待(dai)混(hun)(hun)凝(ning)(ning)土澆(jiao)筑(zhu)(zhu)后(hou)6小(xiao)時用棉布,草(cao)垛覆蓋,并(bing)澆(jiao)水保(bao)養,平均2小(xiao)時澆(jiao)一(yi)次水。(11)待(dai)混(hun)(hun)凝(ning)(ning)土澆(jiao)筑(zhu)(zhu)后(hou)3天(tian)把外模(mo)板(ban)拆(chai)除(chu)(chu),7天(tian)后(hou)拆(chai)除(chu)(chu)內模(mo)板(ban)并(bing)繼續保(bao)養,不可過重型(xing)機械。(12)安(an)裝電(dian)(dian)纜(lan)(lan)(lan)支架。
(二)電纜敷設管理
1.敷設問(wen)題導致的故障
10kV 線路#1線出(chu)線至(zhi)開(kai)閉所進行(xing)開(kai)關(guan)C相故(gu)(gu)障,原因是(shi)電纜絕(jue)緣(yuan)及(ji)銅(tong)屏蔽處燒毀嚴重,導致(zhi)單相接(jie)地故(gu)(gu)障。經過對比分析,電纜線芯有外凸現象,懷疑(yi)是(shi)由于電纜敷設過程中,轉(zhuan)彎半徑不足,導致(zhi)電纜線芯及(ji)絕(jue)緣(yuan)層(ceng)長期受(shou)力,在電力場的作用下,最終導致(zhi)外凸處絕(jue)緣(yuan)老化擊穿(chuan)。
2電纜(lan)敷設管(guan)理建議
各施(shi)(shi)工(gong)單位要采取有效措施(shi)(shi),加(jia)(jia)強對(dui)電(dian)纜(lan)(lan)(lan)敷(fu)設人員的管(guan)理,加(jia)(jia)強電(dian)纜(lan)(lan)(lan)施(shi)(shi)工(gong)質量監督。項目經理在施(shi)(shi)工(gong)單位敷(fu)設電(dian)纜(lan)(lan)(lan)過程中(zhong)應安排電(dian)纜(lan)(lan)(lan)班中(zhong)間驗收,針對(dui)電(dian)纜(lan)(lan)(lan)敷(fu)設,要求施(shi)(shi)工(gong)單位牽引(yin)時使(shi)用壓力表(biao),防止(zhi)暴力牽引(yin)電(dian)纜(lan)(lan)(lan),對(dui)電(dian)纜(lan)(lan)(lan)本體造(zao)成(cheng)損傷(shang),電(dian)纜(lan)(lan)(lan)轉(zhuan)彎處使(shi)用導(dao)向滑輪,禁止(zhi)在轉(zhuan)彎井及頂管(guan)井內制作中(zhong)間接頭等。